Objective: Remove burrs from the front and rear of machined drills for Arthroscopy scissors.
The Arthroscopy scissor Joint is a reusable system that integrates advanced quality, durability, and precise tactility in each instrument to provide an optimal solution for every angle.
Application details:
Material: 17-4 PH, Wr N.1.4542
Pilot Holes: Ø2.5 and Ø3.0mm / .098 and .315”
Pilot Holes Length: H1=20mm and H2=6mm / .787” and .236”
Machine: DMG MURI CMX 50U
Production Volume: 7000 bores/month
Tool-holder Sets:
UB2500; UBS-d025-C08-H29-L65
UB3000; UBS-d030-C08-H29-L85
Blades:
UB2022; UB-TSB-2.5-PL-NCT
UB2032; UBS-TSB-3.0-PL-NCT
Machining Parameters:
Ød
Pilot-Hole
S
Spindle Speed
F
Table Feed
vc
Cutting Speed
fz
Feed per tooth
Coolant
mm
Inch
RPM
mm/min
inch/min.
m/min.
sfm
mm
inch
2.5
0.098
2000
500
20
16
52
0.25
0.01
External Emulsion
3.0
0.118
2000
500
20
19
62
0.25
0.01
External Emulsion
Results: The burrs were effectively eliminated, leaving 0.2×45° chamfers.
The customer can save roughly ~20 hours on manual work in 1 month.