UBURR MACHINE

Case Study #3 UBURR

Industry: Medical

Objective: Remove burrs from the front and rear of machined drills for Arthroscopy scissors.

The Arthroscopy scissor Joint is a reusable system that integrates advanced quality, durability, and precise tactility in each instrument to provide an optimal solution for every angle.

Application details:

  • Part: Transmission Carrier Assembly
  • Material: 17-4 PH, Wr N.1.4542
  • Pilot Holes: Ø2.5 and Ø3.0mm / .098 and .315”
  • Pilot Holes Length: H1=20mm and H2=6mm / .787” and .236”
  • Machine: DMG MURI CMX 50U
  • Production Volume: 7000 bores/month

Tools:

  • UB2180MS; UB-d025-C08-H29-L65

Blade: UB2030; UB-TSB-3-PL

Machining Parameters:

Ød

Pilot-Hole

S

Spindle Speed

F

Table Feed

vc

Cutting Speed

fz

Feed per tooth

 

Coolant

mm

Inch

RPM

mm/min

inch/min.

m/min.

sfm

mm

inch

2.5

0.098

3200

480

19

25

82

0.15

0.01

External Emulsion

3.0

0.315

3200

480

19

30

99

0.15

0.01

External Emulsion

Results: The burrs were effectively eliminated, leaving 0.2×45° chamfers.

The customer can save roughly ~20 hours on manual work in 1 month.